Timer Module with Event Logger
The level crossing gates at present are all manually operated. The negligence of rules from some gate men has been a cause of accidents. To prevent these accidents and negligence, some level of check has to be brought in the level crossing gates. There is a need for devices to be installed at the level crossing to provide a timer based release mechanism of the gate and data logging of the events in the LC Gate.
- 5 SP contact input data logging in the system
- Surge Protection from input power supply (36 to 90V).
- Potential Free Contacts to Monitor Relay Status
- Data Communication and transfer of events logged to the external device through BLE/Bluetooth/RS232
- The over voltage and under voltage event logged and send alerts
- Level Crossing Gate Timer Control
- Event Monitoring
- Relay Room Monitoring
Front End Processor - Inputs & Outputs:
- 5 channel input data logging in the system
- Relay Based output Mechanism to Control the key
- Two parallel relays
- To take care of any redundancy features
- Emergency Override
- In case if this signal is activated, the circuit will revert to a FAIL-SAFE mode of operation.
- Fail Safe mechanism to release the gate in case the relays fail to release the key
- This event will get logged and send alerts
- This will be an external feature. Not related to the LC Gate Module.
- LEDs
- Showing the different modes of operation
- Power Supply taken from the 24V DC power input line
- The system will have to work with 12 Hours power backup.
Power Supply
- Power Supply taken from the 24V DC power input line
- Surge Protection from input power supply (36 to 90V)
- Isolated Power supply
- Onboard battery – to take care of intermittent power failures (Optional)
Time Delay
- Programmable Jumper Based Key Release Mechanism
- The delay duration can be selected from any one of the following 3 settings
- 30 sec
- 60 sec
- 120 sec
- This will be selectable, through a 3 position switch.
- This switch will be mounted inside the enclosure
- To support totally 5 inputs(Potential Free contact)
- Potential Free Contacts to Monitor Relay Status
- Analog Input to Monitor Power Supply
- The analog data will be logged in steps of 0.5V
- The over voltage and under voltage event logged and send alerts
- The data will be sampled at the occurrence of every event
- Data logger configuration through Bluetooth/Mobile/RS-232
- Mobile Number Configuration(15 numbers)
- PF contact configuration (5 PF)
- GateID configuration
- Data back-up with built-in RTC (Real Time Clock) for storing the records
- Based on time stamping
- The data will be stored in its onboard memory
- For a minimum period of 3 months
- The data will be stored on FIFO based approach
- Onboard battery – to take care of intermittent power failures
- Up-to 2 days of event logging
- Data Communication and transfer of events logged to the external device through BLE
- A suitable Handheld device with the associated software
- The required data exchange will be through the BLE interface
- To obtain the logged event data through the handheld device at time periods fixed by the customer
- RS232 interface, will be provided, as optional interface as an alternate provision